ANALISIS AUDIT ENERGI PADA SISTEM TENAGA LISTRIK DI RUMAH SAKIT CIREMAI KOTA CIREBON

Izzuddin Al Qossam, - (2018) ANALISIS AUDIT ENERGI PADA SISTEM TENAGA LISTRIK DI RUMAH SAKIT CIREMAI KOTA CIREBON. S1 thesis, Universitas Pendidikan Indonesia.

[img] Text
S_TE_1303988_Title.pdf

Download (95kB)
[img] Text
S_TE_1303988_Table_of_Content.pdf

Download (79kB)
[img] Text
S_TE_1303988_Abstract.pdf

Download (82kB)
[img] Text
S_TE_1303988_Chapter1.pdf

Download (123kB)
[img] Text
S_TE_1303988_Chapter2.pdf
Restricted to Staf Perpustakaan

Download (269kB)
[img] Text
S_TE_1303988_Chapter3.pdf

Download (78kB)
[img] Text
S_TE_1303988_Chapter4.pdf
Restricted to Staf Perpustakaan

Download (1MB)
[img] Text
S_TE_1303988_Chapter5.pdf

Download (64kB)
[img] Text
S_TE_1303988_Bibliography.pdf

Download (111kB)
[img] Text
S_TE_1303988_Appendix.pdf
Restricted to Staf Perpustakaan

Download (586kB)
Official URL: http://repository.upi.edu

Abstract

Industri rumah sakit merupakan suatu jenis usaha berbasis pelayanan kesehatan yang didalam operasionalnya membutuhkan energi listrik yang tinggi. Besarnya energi listrik yang tinggi mengakibatkan biaya pengeluaran juga tinggi. Rumah sakit Ciremai merupakan rumah sakit umum tipe B untuk tingkat wilayah III yang mengakibatkan tingkat hunian tinggi. Oleh karenanya kebutuhan energi listrik menjadi kebutuhan primer. Tarif dasar listrik yang semakin naik menjadi suatu masalah dalam biaya pengeluaran rumah sakit. Maka kegiatan audit energi perlu dilakukan untuk mengetahui seberapa efisien pemakaian energi pada rumah sakit Ciremai melalui pemakaian peralatan listriknya. Metode audit energi awal akan memberi nilai awal dari Intensitas Konsumsi Energi (IKE) suatu bangunan gedung yang akan menentukan sudah efisienkah atau belum, yang kemudian dilanjutkan dengan audit energi rinci untuk mencari peluang penghematan energi listrik yang ada. Hasil dari penelitian ini menunjukkan bahwa rumah sakit Ciremai sudah tergolong efisien pada IKE-nya, namun terdapat peluang penghematan energi pada bagian penyejuk udara dan rekomendasi untuk perancangan ulang pada bagian pencahayaan. ..... Hospital industry is a kind of health-based business which in its operation require high electrical energy. The amount of high electrical energy resulted in high cost of expenditure. Ciremai hospital is a type B public hospital for region III which resulted in high occupancy rate. Therefore the need for electrical energy becomes the primary need. Basic electricity tariffs are increasingly becoming a problem in the cost of hospital expenses. Then the energy audit activities need to be done to find out how efficient the use of energy at hospital Ciremai through the use of electrical equipment. The initial energy audit method will give an initial value of the Energy Consumption Intensity (IKE) of a building that will determine whether it is efficient or not, which then proceed with a detailed energy audit to look for opportunities for energy saving of existing electricity. The results of this study indicate that Ciremai hospital is already efficient in its IKE, but there are energy saving opportunities in the air conditioning section and recommendations for redesign in the lighting section.

Item Type: Thesis (S1)
Additional Information: No. Panggil : S TE IZZ a-2018; Pembimbing I. Bambang Trisno, II. Wasimudin Surya; NIM : 1303988
Uncontrolled Keywords: Audit Energi, Efisiensi Energi, Intensitas Konsumsi Energi, Energy Audit, Energy Efficiency, Energy Consumption Intensity
Subjects: T Technology > T Technology (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Pendidikan Teknologi dan Kejuruan > Jurusan Pendidikan Teknik Elektro > Program Studi Pendidikan Teknik Elektro
Depositing User: Mr Tatang Saja
Date Deposited: 02 Dec 2019 04:49
Last Modified: 02 Dec 2019 04:49
URI: http://repository.upi.edu/id/eprint/43790

Actions (login required)

View Item View Item