DESAIN HYBRID MAGNETIC SENSOR UNTUK MENGUJI JENIS LOGAM

Darusman, Dadan (2013) DESAIN HYBRID MAGNETIC SENSOR UNTUK MENGUJI JENIS LOGAM. S1 thesis, Universitas Pendidikan Indonesia.

[img]
Preview
Text
S_FIS_0608457_title.pdf

Download (101kB) | Preview
[img]
Preview
Text
S_FIS_0608457_abstract.pdf

Download (100kB) | Preview
[img]
Preview
Text
S_FIS_0608457_table of content.pdf

Download (175kB) | Preview
[img]
Preview
Text
S_FIS_0608457_chapter 1.pdf

Download (174kB) | Preview
[img] Text
S_FIS_0608457_chapter 2.pdf
Restricted to Staf Perpustakaan

Download (353kB)
[img]
Preview
Text
S_FIS_0608457_chapter 3.pdf

Download (109kB) | Preview
[img] Text
S_FIS_0608457_chapter 4.pdf
Restricted to Staf Perpustakaan

Download (255kB)
[img]
Preview
Text
S_FIS_0608457_chapter 5.pdf

Download (92kB) | Preview
[img]
Preview
Text
S_FIS_0608457_bibliography.pdf

Download (216kB) | Preview
[img] Text
S_FIS_0608457_appendix.pdf
Restricted to Staf Perpustakaan

Download (121kB)

Abstract

Telah dibuat hybrid magnetic sensor untuk mendeteksi jenis logam dengan menggunakan sistem koil solenoida dan sensor magnetik GMR tipe A002-02. Desain hybrid magnetic sensor adalah salah satu alat untuk medeteksi jenis logam dengan menggunakan sistem sensor hybrid yang didasarkan pada hukum Faraday yaitu ketika kawat dialiri arus maka akan timbul medan magnet. Kawat dibuat dengan sistem solenoida yang diberi arus DC kemudian medan magnet yang dihasilakn di-sensing oleh sensor magnetik GMR A002-02. Untuk mengetahui apakah sensor magnetik GMR A002-02 bekerja dengan baik maka dilakukan uji sensitivitas dan didapat sensitivitas dari sensor magnetik GMR A002-02 sebesar 32.65mV/A dengan nilai histerisis sebesar 5%. Untuk uji jenis logam, maka pada solenoida dimasukan berbagai jenis logam sehingga diketahui perubahan medan magnet yang terjadi berupa keluaran tegangan dari sensor magnetik GMR. Karena keluaran dari sensor magnetik GMR dalam orde mili volt, maka dikuatkan dengan rangkaian penguat sehingga keluarannya menjadi orde volt. Rangkaian penguat yang digunakan adalah rangkaian penguat inverting dengan penguatan 53,61 kali. Dari hasil pengukuran didapat untuk jenis logam tembaga sebesar 0.867V, logam aluminium sebesar 1.888V, logam kuningan sebesar 2.562V, logam stainless sebesar 2.657V, dan logam besi sebesar 5.82V. Kata Kunci: Medan Magnet, Koil Solenoida, Sensor GMR, Hybrid Sensor Have made the hybrid magnetic sensor to detect the type of metal by using a solenoid coil system and a GMR magnetic sensor type A002-02. Hybrid magnetic sensor design is one tool for detecting metals using hybrid sensor system based on Faraday's law that when energized wire will arise magnetic field. Made with wire systems DC solenoid is energized then the magnetic field-sensing by dihasilakn in GMR magnetic sensor A002-02. To determine whether the GMR magnetic sensor A002-02 works well then tested the sensitivity and sensitivity obtained from GMR magnetic sensor A002-02 at 32.65mV/A with a hysteresis value of 5%. To test the type of metal, then the solenoid included various types of metals that are known to changing magnetic fields that occur in the form of the output voltage of GMR magnetic sensor. Because the output of GMR magnetic sensors in order milli volts, then amplified by the amplifier circuit that outputs a volt order. Used amplifier circuit is an inverting amplifier with a gain 53.61 times. From the measurement results obtained for the type of copper equal to 0.867V, 1.888V for aluminum metal, brass metal at 2.562V, 2.657V for stainless steel, and iron equal to 5.82V. Keywords: Magnetic Fields, solenoid coil, GMR Sensor, Hybrid Sensor

Item Type: Thesis (S1)
Subjects: Universitas Pendidikan Indonesia > Fakultas Pendidikan Matematika dan Ilmu Pengetahuan Alam > Jurusan Pendidikan Fisika > Program Studi Pendidikan Fisika
Divisions: Fakultas Pendidikan Matematika dan Ilmu Pengetahuan Alam > Jurusan Pendidikan Fisika > Program Studi Pendidikan Fisika
Depositing User: DAM STAF Editor
Date Deposited: 02 Oct 2013 03:51
Last Modified: 02 Oct 2013 03:51
URI: http://repository.upi.edu/id/eprint/1990

Actions (login required)

View Item View Item