PENGARUH ECCENTRICALLY BRACED FRAME (EBF) LINK HORIZONTAL DAN LINK VERTIKAL TERHADAP PERILAKU STRUKTUR GEDUNG GUNUNG GEULIS SEJAHTERA HOTEL

Yoshita Tri Bintang, - (2023) PENGARUH ECCENTRICALLY BRACED FRAME (EBF) LINK HORIZONTAL DAN LINK VERTIKAL TERHADAP PERILAKU STRUKTUR GEDUNG GUNUNG GEULIS SEJAHTERA HOTEL. S1 thesis, Universitas Pendidikan Indonesia.

[img] Text
S_TS_1900712_Title.pdf

Download (1MB)
[img] Text
S_TS_1900712_Chapter 1.pdf

Download (141kB)
[img] Text
S_TS_1900712_Chapter 2.pdf
Restricted to Staf Perpustakaan

Download (1MB)
[img] Text
S_TS_1900712_Chapter 3.pdf

Download (501kB)
[img] Text
S_TS_1900712_Chapter 4.pdf
Restricted to Staf Perpustakaan

Download (2MB)
[img] Text
S_TS_1900712_Chapter 5.pdf

Download (59kB)
[img] Text
S_TS_1900712_Appendix.pdf
Restricted to Staf Perpustakaan

Download (3MB)
Official URL: http://repository.upi.edu

Abstract

Sistem EBF merupakan struktur portal baja dengan ujung pengaku berpotongan dengan balok membentuk eksentrisitas horizontal tertentu dari joint yang disebut link. Sistem EBF menjadikan link sebagai elemen utama penyerap energi gempa yang mengalami kerusakan terlebih dahulu dari elemen lainnya. Tipe link yang paling sering digunakan adalah horizontal. Namun, untuk beberapa kasus, struktur dengan link horizontal tidak dapat diterapkan pada beberapa lantai yang harus mampu memikul beban vertikal besar. Selain itu, penggantian link yang mengalami kerusakan pada EBF-H bisa sangat sulit karena link menjadi satu kesatuan dengan balok. Oleh karena itu diusulkan penggunaan link secara vertikal pada sistem EBF. Tugas akhir ini akan menganalisis perlaku struktur EBF dengan tipe link horizontal dan vertikal. Struktur yang dimodelkan adalah hotel 7 lantai dengan pembebanan gempa respons spektrum dan pushover. Dari analisis respons spektrum diperoleh bahwa simpangan yang terjadi pada EBF-H dan EBF-V berkurang sebanyak 51% dan 49% dari simpangan struktur eksisting. Sementara itu, melalui analisis pushover dapat diketahui sendi plastis (leleh) pertama terjadi pada elemen link. Perilaku inelastik struktur pada analisis pushover menunjukkan hasil bahwa kekuatan, kekakuan, dan daktilitas struktur EBF Link Horizontal (Model II) lebih baik dibandingkan dengan struktur EBF Link Vertikal. Level kinerja EBF-H dan EBF-V pada pembebanan gempa respons spektrum adalah Immediate Occupancy, sementara pada pembebanan metode pushover level kinerja EBF-H adalah Damage Control dan untuk EBF-V adalah Life Safety. Dengan adanya perencanaan link, balok di luar link, kolom, dan pengaku pada sistem EBF, struktur dapat memiliki berat yang lebih ringan, juga memiliki kekuatan, kekakuan, dan daktilitas yang lebih baik. : The EBF system is a steel frame structure with the ends of the braces intersecting the beams forming a certain horizontal eccentricity of the joints called links. The EBF system makes the link as the major seismic energy dissipating element which is damaged earlier than other elements. The most common type of link is horizontal link. However, for some cases, structures with horizontal links cannot be applied to several floors which must be able to carry large vertical loads. In addition, replacing damaged links on the EBF-H can be very difficult because the links become one unit with the beam. Therefore, it is proposed to use a vertical link in the EBF system. This final thesis will analyze the behavior of the EBF structure with horizontal and vertical links. The system structure is modeled as a structure of 7 floors and function as a hotel with a response spectrum and pushover analysis. From the response spectrum analysis, it was found that the horizontal drift that occurred in EBF�H and EBF-V were reduced by 51% and 49% of the deviations in the existing structure. Meanwhile, through pushover analysis it can be seen that the first plastic hinge (yield) occurs in the link elements. The inelastic behavior of the structure in the pushover analysis shows that the strength, stiffness, and ductility of the Horizontal Link EBF structure (Model II) are better than the Vertical Link EBF structure. The performance level of EBF-H and EBF-V under seismic response spectrum analysis is Immediate Occupancy, while for pushover analysis, the performance level for EBF-H is Damage Control and for EBF-V is Life Safety. By re-designing the beam outside the links, columns and diagonal braces in the EBF system, the structure can have a lighter weight, as well as have better strength, stiffness and ductility.

Item Type: Thesis (S1)
Additional Information: https://scholar.google.com/citations?view_op=new_articles&hl=id&imq=Yoshita+Tri+Bintang# Budi Kudwadi: 5995921 Ben Novarro Batubara: 6710018
Uncontrolled Keywords: eccentrically braced frame, link horizontal, link vertikal, analisis respons spektrum, analisis pushover, perilaku struktur horizontal link, vertical link, response spectrum analysis, pushover analysis, structural behavior
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Pendidikan Teknologi dan Kejuruan > Jurusan Pendidikan Teknik Sipil > Program Studi Teknik Sipil
Depositing User: Yoshita Tri Bintang
Date Deposited: 16 Oct 2023 04:04
Last Modified: 16 Oct 2023 04:04
URI: http://repository.upi.edu/id/eprint/109869

Actions (login required)

View Item View Item