eprintid: 143942 rev_number: 22 eprint_status: archive userid: 220752 dir: disk0/00/14/39/42 datestamp: 2025-10-23 02:05:21 lastmod: 2025-10-23 02:05:21 status_changed: 2025-10-23 02:05:21 type: thesis metadata_visibility: show creators_name: Alfi Noviar Ilhami, - creators_name: Tasma Sucita, - creators_nim: NIM2101210 creators_nim: NIDN0007106402 creators_id: alfinoviarilham@upi.edu creators_id: tasmasucita@upi.edu contributors_type: http://www.loc.gov/loc.terms/relators/THS contributors_name: Tasma Sucita, - contributors_nidn: NIDN0007106402 contributors_id: tasmasucita@upi.edu title: ANALISIS PENGUJIAN KESEREMPAKAN DAN CONTACT BOUNCE PEMUTUS TENAGA (PMT) 20KV MENGGUNAKAN BREAKER ANALYZER ispublished: pub subjects: L1 subjects: T1 subjects: TK divisions: JPTE full_text_status: restricted keywords: Pemutus tenaga, keserempakan kontak, contact bounce, breaker analyzer. Circuit breaker, contact synchronization, contact bounce, breaker analyzer. note: https://scholar.google.com/citations?hl=en&user=bdGvhnkAAAAJ&view_op=list_works&gmla=AH8HC4yQQjw9z2LI0XRBRA32H01j8y0CQKv-Em7n1yxf4wwmWPu4K9N3sBx34-p96JDuNvkmj7W3mAz6feJSZtntGNJGqkM3ZKG2ApljPFzdMjc2dGGXvH3ILqGijLf6GA_Cluo ID Sinta Dosen Pembimbing: Tasma Sucita: 0007106402 abstract: Pemutus Tenaga (PMT) merupakan komponen krusial dalam sistem tenaga listrik, khususnya di jaringan distribusi 20 kV yang berfungsi sebagai pengaman dan pemutus arus. Kinerja PMT yang optimal sangat penting untuk menjamin keandalan serta keamanan sistem. Penelitian ini menggunakan metode deskriptif analitik dan bertujuan untuk mengetahui cara kerja PMT, menganalisis kinerja PMT melalui pengujian keserempakan kontak, dan pengujian contact bounce. Pengujian dilakukan di PMT 20 kV yang terdapat di Gardu Induk GIS Gedebage dan GIS Cibabat Baru dengan menggunakan parameter yang dihasilkan dari alat uji Breaker Analyzer. Pengujian keserempakan kontak dilakukan dengan mengukur waktu kerja kontak open dan close dan pengujian waktu contact bounce dilakukan hanya ketika PMT dalam proses menutup kontaknya. Data pengujian akan dianalisis dan dibandingkan dengan standar yang dikeluarkan oleh PLN dan masing-masing manufaktur PMT. Temuan penelitian menunjukkan untuk PMT yang terdapat di Gardu Induk GIS Gedebage memiliki anomali dalam keserempakan kontaknya serta waktu contact bounce yang dihasilkan dari alat uji. Sementara itu, untuk PMT yang terdapat di Gardu Induk GIS Cibabat Baru sudah sesuai memenuhi standar PLN dan standar yang dikeluarkan oleh manufaktur, serta menunjukkan PMT masih dalam kondisi aman dan layak untuk dioperasikan. Circuit Breakers (CB) are crucial components in electrical power systems, especially in 20 kV distribution networks, functioning as safety devices and current interrupters. Optimal CB performance is essential to ensure system reliability and safety. This research employs a descriptive analytical method and aims to understand the working principle of CBs and analyze their performance through contact synchronism testing and contact bounce testing. The tests were conducted on 20 kV CBs located at the Gedebage GIS Substation and Cibabat Baru GIS Substation using parameters obtained from a Breaker Analyzer. Contact synchronism testing was performed by measuring the open and close contact operating times, and contact bounce time testing was conducted only when the CB was in the process of closing its contacts. The test data will be analyzed and compared with standards issued by PLN and each CB manufacturer. Research findings indicate that the CB at the Gedebage GIS Substation show anomalies in their contact synchronism and the contact bounce time measured by the test equipment. Meanwhile, the CB at the Cibabat Baru GIS Substation meet PLN and manufacturer standards, indicating that the CBs are still in a safe and operable condition. date: 2025-08-25 date_type: published institution: Universitas Pendidikan Indonesia department: KODEPRODI20201#Teknik Elektro_S1 thesis_type: other thesis_name: other official_url: https://repository.upi.edu/ related_url_url: https://perpustakaan.upi.edu related_url_type: org citation: Alfi Noviar Ilhami, - and Tasma Sucita, - (2025) ANALISIS PENGUJIAN KESEREMPAKAN DAN CONTACT BOUNCE PEMUTUS TENAGA (PMT) 20KV MENGGUNAKAN BREAKER ANALYZER. S1 thesis, Universitas Pendidikan Indonesia. document_url: http://repository.upi.edu/143942/1/S_TE_2101210_Title.pdf document_url: http://repository.upi.edu/143942/2/S_TE_2101210_Chapter1.pdf document_url: http://repository.upi.edu/143942/3/S_TE_2101210_Chapter2.pdf document_url: http://repository.upi.edu/143942/4/S_TE_2101210_Chapter3.pdf document_url: http://repository.upi.edu/143942/5/S_TE_2101210_Chapter4.pdf document_url: http://repository.upi.edu/143942/6/S_TE_2101210_Chapter5.pdf document_url: http://repository.upi.edu/143942/7/S_TE_2101210_Appendix.pdf