Gilang Kencana Yustisia, - (2023) ANALISIS PEMELIHARAAN DAN PENEMPATAN LIGHTNING ARRESTER BAY UJUNG BERUNG 1 GARDU INDUK 150 KV DAGO PAKAR. S1 thesis, Universitas Pendidikan Indonesia.
Text
S_TE_1807633_Title.pdf Download (340kB) |
|
Text
S_TE_1807633_Chapter1.pdf Download (216kB) |
|
Text
S_TE_1807633_Chapter2.pdf Restricted to Staf Perpustakaan Download (1MB) |
|
Text
S_TE_1807633_Chapter3.pdf Download (369kB) |
|
Text
S_TE_1807633_Chapter4.pdf Restricted to Staf Perpustakaan Download (1MB) |
|
Text
S_TE_1807633_Chapter5.pdf Download (184kB) |
|
Text
S_TE_1807633_Appendix.pdf Restricted to Staf Perpustakaan Download (15MB) |
Abstract
Berbagai macam faktor dapat mempengaruhi penurunan keandalan Lightning Arrester seperti banyaknya debu polutan yang menempel, korosi pada beberapa bagian, tidak berfungsinya peralatan, dan pengaruh jarak Lightning Arrester dengan peralatan yang dilindunginya. Masalah-masalah tersebut terjadi pula pada Lightning Arrester Bay Ujung Berung 1 Gardu Induk Dago Pakar. Penempatan Lightning Arrester di gardu induk tegangan tinggi dapat ditentukan melalui beberapa evaluasi dan proses desain gardu induk. Penelitian ini bertujuan untuk mengetahui pelaksanaaan pemeliharaan peralatan Lightning Arrester di Gardu Induk Dago Pakar dan mengetahui jarak optimum penempatan Lightning Arrester terhadap peralatan yang dilindungi. Metode yang digunakan pada penelitian ini adalah dengan cara membandingkan data yang diperoleh di lapangan dengan studi literatur yang dilakukan. Berdasarkan dari penemuan dan pembahasan diperoleh pemeliharaan telah dilakukan dengan cukup baik. Pada inspeksi level 1, inspeksi level 2, dan inspeksi level 3 yang mana semua dilakukan dengan baik dan sesuai dengan SOP. Namun ada beberapa masalah seperti beberapa parameter pada pemeliharaan tidak dilaksanakan, naiknya nilai tahanan pentanahan dikarenakan korosi di beberapa bagian, dan tidak berfungsinya Surge Counter yang perlu dilakukan pergantian atau perbaikan dengan segera. Pada jarak penempatan Lightning Arrester Bay Ujung Berung 1 Gardu Induk 150 kV Dago Pakar Lightning Arrester kurang dapat melindungi peralatan yang dilindunginya. CVT, PMS, CT dapat terlindungi dengan sangat baik namun pada PMT yang jaraknya melebihi perlindungan dengan probabilitas 50% akan mengalami masalah. Jarak penempatan Lightning Arrester ini kurang memenuhi kriteria sesuai pada SPLN T5.007. Perlunya pengujian ulang dengan menggunakan metode yang berbeda atau pergantian unit agar dapat melindungi semua perlatan dengan baik. : Various factors can affect the reliability of the Lightning Arrester, such as the amount of pollutant dust adhering to it, corrosion in some parts, equipment malfunctions, and the effect of the Lightning Arrester's distance from the equipment it protects. These problems also occurred at Lightning Arrester Bay Ujung Berung 1 Dago Pakar Substation. Placement of Lightning Arrester in high voltage substations can be determined through several substation evaluation and design processes. This study aims to determine the implementation of maintenance of Lightning Arrester equipment at the Dago Pakar Substation and determine the optimum distance for Lightning Arrester placement to protected equipment. The method used in this research is to compare the data obtained in the field with the literature study conducted. Based on the findings and discussion, it was found that maintenance had been carried out quite well. At level 1 inspections, level 2 inspections, and level 3 inspections which were all carried out properly and in accordance with the SOP. However, there are a number of problems such as several parameters for maintenance not being carried out, an increase in the value of ground resistance due to corrosion in several parts, and a malfunction of the Surge Counter which needs to be replaced or repaired immediately. At the distance of Lightning Arrester Bay Ujung Berung 1 150 kV Substation Dago Expert Lightning Arrester is less able to protect the equipment it protects. CVT, PMS, CT can be protected very well but PMT which is far beyond the protection with a probability of 50% will experience problems. This Lightning Arrester placement distance does not meet the criteria according to SPLN T5.007. The need for retesting using a different method or replacing the unit in order to properly protect all equipment.
Item Type: | Thesis (S1) |
---|---|
Additional Information: | https://scholar.google.com/citations?hl=id&authuser=1&user=fBlDhtQAAAAJ SINTA ID : 5993914 SINTA ID : 6003437 |
Uncontrolled Keywords: | Lightning Arrester, Pemeliharaan, Jarak penempatan Maintenance, Placement Distance |
Subjects: | L Education > L Education (General) T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Fakultas Pendidikan Teknologi dan Kejuruan > Jurusan Pendidikan Teknik Elektro > Program Studi Teknik Tenaga Elektrik |