KOORDINASI RELAY OCR, GFR DAN RECLOSER PASCA UPRATING TRANSFORMATOR TENAGA PADA PENYULANG MJO 01 GARDU INDUK MOJOSONGO

Ilyas Habil Agnia, - (2022) KOORDINASI RELAY OCR, GFR DAN RECLOSER PASCA UPRATING TRANSFORMATOR TENAGA PADA PENYULANG MJO 01 GARDU INDUK MOJOSONGO. S1 thesis, Universitas Pendidikan Indonesia.

[img] Text
S_TE_1600308_Title.pdf

Download (317kB)
[img] Text
S_TE_1600308_Chapter1.pdf

Download (122kB)
[img] Text
S_TE_1600308_Chapter2.pdf
Restricted to Staf Perpustakaan

Download (392kB) | Request a copy
[img] Text
S_TE_1600308_Chapter3.pdf

Download (157kB)
[img] Text
S_TE_1600308_Chapter4.pdf
Restricted to Staf Perpustakaan

Download (683kB) | Request a copy
[img] Text
S_TE_1600308_Chapter5.pdf

Download (54kB)
[img] Text
S_TE_1600308_Appendix.pdf
Restricted to Staf Perpustakaan

Download (82kB) | Request a copy
Official URL: http://repository.upi.edu

Abstract

Electrical energy is a very important resource. All human activities can not be separated from electrical energy. PT PLN is required to provide good service by ensuring the continuity of electricity distribution to consumers so that the electrical power reliability system can be maintained The reliability parameter of the electricity can be seen by the frequent of interrupts/blackouts occurred. Blackouts can be caused by the short circuit in the power system. To minimalize the short circuit, it needs a protection system which is well-coordinated from the power plants to the distribution lines. The study of protection system coordination on feeder MJO 01 from Gardu Induk Mojosongo is written in this paper using manual calculations and simulations on the ETAP 16.0.0 application.The aims of this study is to know the magnitude of short circuit that occurred on the lines, that it can be used to calculate the current and time setting of the OCRs, GFRs and reclosers. The coordination setting of relays in this paper is located on the incoming feeder, outgoing feeder, and recloser.The best coordination of the protection system is the coordination which each relay can be worked in sequence, without overlap occurred from the feeder to the incoming feeder. The result of this study is the time setting (tripping time) of the relays from the recloser to the incoming feeder is increasing and the overlapping is not occurred.

Item Type: Thesis (S1)
Uncontrolled Keywords: GI Mojosongo, gangguan hubung singkat, koordinasi sistem proteksi, Over Current Relay (OCR), Ground Fault relay (GFR), recloser, ETAP 16.0.0.
Subjects: L Education > L Education (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Pendidikan Teknologi dan Kejuruan > Jurusan Pendidikan Teknik Elektro > Program Studi Teknik Tenaga Elektrik
Depositing User: Ilyas Habil Agnia
Date Deposited: 02 Feb 2022 06:58
Last Modified: 02 Feb 2022 06:58
URI: http://repository.upi.edu/id/eprint/70726