PENGARUH BENTUK BUFFLE BLOCK TERHADAP REDAMAN ENERGI PADA MERCU TIPE OGEE

Meca Bella Monica, - (2018) PENGARUH BENTUK BUFFLE BLOCK TERHADAP REDAMAN ENERGI PADA MERCU TIPE OGEE. S1 thesis, Universitas Pendidikan Indonesia.

[img] Text
TA_TS_1406778_Title.pdf

Download (209kB)
[img] Text
TA_TS_1406778_Abstract.pdf

Download (400kB)
[img] Text
TA_TS_1406778_Table_of_Contents.pdf

Download (537kB)
[img] Text
TA_TS_1406778_Chapter1.pdf

Download (212kB)
[img] Text
TA_TS_1406778_Chapter2.pdf
Restricted to Staf Perpustakaan

Download (1MB)
[img] Text
TA_TS_1406778_Chapter3.pdf

Download (995kB)
[img] Text
TA_TS_1406778_Chapter4.pdf
Restricted to Staf Perpustakaan

Download (1MB)
[img] Text
TA_TS_1406778_Chapter5.pdf

Download (108kB)
[img] Text
TA_TS_1406778_Bibliography.pdf

Download (108kB)
[img] Text
TA_TS_1406778_Appendix.pdf
Restricted to Staf Perpustakaan

Download (2MB)
Official URL: http://repository.upi.edu

Abstract

Untuk meredam gerusan di hilir stilling basin, maka di pasang Buffle Block pada kolam olak. Untuk tujuan ini diperlukan penelitian pada bendung dengan mercu tipe ogee dan untuk menguji efektifitas Buffle Block dalam mereduksi energi aliran, panjang loncatan, yang paling efektif dan ekonomis sebagai redaman energi. Penelitian dilanjutkan dengan metode eksperimen, dengan berbagai variasi debit dan pada Buffle Block. Penelitian ini dilakukan di Laboratorium menggunakan model mercu tipe ogee. Kategori loncatan hidrolik yang dihasilkan berupa oscillating jump, steady jump, dan weak jump. Nilai froude yang terjadi di hilir sebelum menggunakan Buffle Block lebih besar dibandingkan setelah menggunkan peredam energi Buffle Block. Terjadi redaman loncatan hidrolik setelah menggunakan Buffle Block rata-rata sebesar 54,41%. Terjadi pengurangan panjang gerusan (Lmaks) rata-rata sebesar 69,67% dan kedalaman gerusan (ds) rata-rata sebesar 81,31%. Berdasarkan perhitungan efektifitas model bahwa desain peredam energi Buffle Block tipe Z (run 4) paling efektif sebagai peredam energi, dan diperuntukan untuk mengurangi local scouring.;--To reduce scouring down the stilling basin, Buffle Block was installed in the oak pond. For this purpose research is needed on ogee-type weir dams and to test the effectiveness of Buffle Block in reducing energy flow, stepping length, which is the most effective and economical as energy attenuation. The study continued with the experimental method, with various variations of discharge and on Buffle Block. This research was conducted at the Laboratory using the ogee type mercury model. The hydraulic jumping categories produced were oscillating jumps, steady jumps and weak jumps. The froude value that occurs downstream before using the Buffle Block is greater than after using the Buffle Block energy damper. There was a hydraulic jump attenuation after using Buffle Block on average 54.41%. There was a reduction in the scour length (Lmaks) averaging 69.67% and scour depth (ds) averaging 81.31%. Based on the calculation of the effectiveness of the model that the Buffle Block type Z (run 4) energy reducer design is most effective as an energy reducer, it is intended to reduce local scouring.

Item Type: Thesis (S1)
Additional Information: No. Panggil : S TS MEC p-2018; Pembimbing : I. Rakhmat Yusuf, II. Mardiani; NIM : 1406778.
Uncontrolled Keywords: Buffle Block, Redaman Energi, Loncatan Hidrolik, Energy Damping, Hydraulic Jump.
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TC Hydraulic engineering. Ocean engineering
Divisions: Fakultas Pendidikan Teknologi dan Kejuruan > Jurusan Pendidikan Teknik Sipil > Program Studi Teknik Sipil
Depositing User: Cintami Purnama Rimba
Date Deposited: 11 Oct 2019 01:26
Last Modified: 11 Oct 2019 01:26
URI: http://repository.upi.edu/id/eprint/40487

Actions (login required)

View Item View Item