ANALISIS TIPE ARUS DAN LOKASI GANGGUAN PADA PENYULANG DISTRIBUSI GI.BANDUNG UTARA

Nugroho, Awaludin (2017) ANALISIS TIPE ARUS DAN LOKASI GANGGUAN PADA PENYULANG DISTRIBUSI GI.BANDUNG UTARA. S1 thesis, Universitas Pendidikan Indonesia.

[img] Text
S_TE_1304289_Title.pdf

Download (312kB)
[img] Text
S_TE_1304289_Abstract.pdf

Download (114kB)
[img] Text
S_TE_1304289_Table_of_content.pdf

Download (258kB)
[img] Text
S_TE_1304289_Chapter1.pdf

Download (226kB)
[img] Text
S_TE_1304289_Chapter2.pdf
Restricted to Staf Perpustakaan

Download (584kB)
[img] Text
S_TE_1304289_Chapter3.pdf

Download (400kB)
[img] Text
S_TE_1304289_Chapter4.pdf
Restricted to Staf Perpustakaan

Download (608kB)
[img] Text
S_TE_1304289_Chapter5.pdf

Download (55kB)
[img] Text
S_TE_1304289_Bibliography.pdf

Download (136kB)
[img] Text
S_TE_1304289_Appendix.pdf
Restricted to Staf Perpustakaan

Download (177kB)
Official URL: http://repository.upi.edu

Abstract

Perubahan kebutuhan energi masyarakat yang meningkat menyebabkan arus gangguan pada penyulang gardu induk. Penelitian ini memaparkan hasil fault diagnosis pada distribution substation feeder menggunakan pendekatan soft computing yaitu, logika fuzzy. Studi fault diagnosis ini dilakukan dengan cara mengolah data arus gangguan dan lokasi titik gangguan pada gardu induk. Data – data tersebut kemudian dijadikan input pembelajaran pada logika fuzzy. Hasil pengujian menunjukan bahwa Fuzzy Rule-Based memiliki tingkat keakuratan yang baik dalam mengindikasi tipe arus gangguan, tetapi tingkat keakuratannya menurun ketika melakukan indikasi lokasi arus gangguan. Changes in the increased energy demand of the community cause a fault current in the substation feeder this research describes fault diagnosis result on distribution substation feeder using soft computing approach, that is fuzzy logic Fault diagnosis study is done by processing the data fault current and the location of the disturbance point on the substation, The data are then used as learning input on fuzzy logic. Test results show that Fuzzy Rule-Based has a good accuracy level in indicating the type of fault current but the accuracy level decreases when indicating the location of the fault current.

Item Type: Thesis (S1)
Additional Information: No. Panggil: S TE NUG a-2017; Pembimbing: I.Yadi Mulyadi, II. Ade Gafar Abdullah; NIM: 1304289
Uncontrolled Keywords: Tipe Arus Gangguan, Lokasi Arus Gangguan, Fuzzy Rule-Based.
Subjects: L Education > L Education (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Pendidikan Teknologi dan Kejuruan > Jurusan Pendidikan Teknik Elektro > Program Studi Pendidikan Teknik Elektro
Depositing User: Mr. Cahya Mulyana
Date Deposited: 28 Aug 2018 01:33
Last Modified: 28 Aug 2018 01:33
URI: http://repository.upi.edu/id/eprint/31248