ANALISIS KUALITAS DAYA DI MUSEUM PENDIDIKAN NASIONAL INDONESIA

Ramdan, Muhammad Alif (2016) ANALISIS KUALITAS DAYA DI MUSEUM PENDIDIKAN NASIONAL INDONESIA. S1 thesis, Universitas Pendidikan Indonesia.

[img]
Preview
Text
S_TE_1105603_Title.pdf

Download (186kB) | Preview
[img]
Preview
Text
S_TE_1105603_Abstract.pdf

Download (126kB) | Preview
[img]
Preview
Text
S_TE_1105603_Table_of_content.pdf

Download (244kB) | Preview
[img]
Preview
Text
S_TE_1105603_Chapter1.pdf

Download (278kB) | Preview
[img] Text
S_TE_1105603_Chapter2.pdf
Restricted to Staf Perpustakaan

Download (1MB)
[img]
Preview
Text
S_TE_1105603_Chapter3.pdf

Download (481kB) | Preview
[img] Text
S_TE_1105603_Chapter4.pdf
Restricted to Staf Perpustakaan

Download (532kB)
[img]
Preview
Text
S_TE_1105603_Chapter5.pdf

Download (203kB) | Preview
[img]
Preview
Text
S_TE_1105603_Bibliography.pdf

Download (264kB) | Preview
[img] Text
S_TE_1105603_Appendix.pdf
Restricted to Staf Perpustakaan

Download (1MB)
Official URL: http://repository.upi.edu

Abstract

Museum Pendidikan Nasional Indonesia merupakan bangunan yang dibangun pada tahun 2012 dan diresmikan pada tahun 2015. Bangunan seluas ±5000 m2 ini memiliki fungsi sebagai lembaga yang menghadirkan karakter dan citra yang berguna untuk kepentingan pendidikan, kebudayaan, dan rekreasi. Museum ini memiliki daya terpasang sebesar 197 kVA dengan tegangan 380 Volt 3 fasa yang disuplai langsung oleh PLN melalui gardu distribusi FPBS UPI. Beban-beban di museum ini beranekaragam diantaranya, penerangan, alat elektronik, lift dan lain-lain. Dengan terpasangnya beban-beban tersebut berdampak terhadap kualitas daya pada sistem kelistrikan di museum. Permasalahan kualitas daya yang terjadi diantaranya, adanya susut tegangan, harmonisa dan rendahnya nilai cos φ. Tujuan dari penelitian ini adalah untuk mengetahui nilai susut tegangan, THD (Total Harmonic Distortion) arus maupun tegangan, mengetahui nilai cos φ, membuat perencanaan pemasangan kapasitor bank dan mengetahui kualitas daya di museum. Metode yang dilakukan dalam penelitian ini adalah perhitungan sederhana untuk mendapatkan nilai kapasitansi daya reaktif yang tepat agar nilai cos φ sebesar 0.99. Hasil dari penelitian ini untuk menaikan cos φ dari 0.8 menjadi 0.99 dibutuhkan kompensasi daya reaktif sebesar 104 kVar dengan menggunakan konfigurasi 18 step kapasitor, sehingga menghasilkan perubahan kualitas daya menjadi lebih baik. Nilai arus sebelum dipasang kapasitor sebesar 285 A, namun setelah dilakukan perancangan kapasitor bank nilai arus menjadi turun sebesar 230.7 A. Turunnya arus memperlihatkan bahwa terjadi perbaikan kualitas daya pada sistem kelistrikan museum. ; Indonesia Museum of National Education (Museum Pendidikan Nasional Indonesia) is a building which was built in 2012 and officiated in 2015. The building with an area of approximately 5000m2 has a function as an institution that presents the characters and imagery that is useful for educational purposes, culture and recreation. The museum has power installed of 197 kVA with 380 Volt 3 Fase which is supplied by the State Electricity Company (PLN) through distribution substation in the Faculty of Language and Literature Education (FPBS) of Indonesia University of Education.The power loads which are installed in the museum are lighting, electronic tools, elevator, etc. The loads installation affects the quality of electrical power system in the Museum. Power quality problems that occurred are drop voltage, harmonic distortion, and the low value of cos φ. The aims of this research are 1) to find out the the low voltage value; 2) to find out the Total Harmonic Distortion (THD) of the current as well as the voltage; 3) to find out the value of cos φ; 4) to create capasitor bank installation planning, and 5) to find out the power quality of the museum. This research employed simple calculation method to get the accurate value of compensation reactive power to get cos φ of 0.99. The result of the research shows that 104 kVar of compensation reactive power by using 18 capacitor steps is needed to increase the value of cos φ from 0.8 to 0.99 so it can produce better quality power change. The current value before installation was 285 A. However it drops to 230 A after capacitor bank installation. The current drops show that there is an improvement on the power qualiy in the electrical system of the musem.

Item Type: Thesis (S1)
Additional Information: No. Panggil: S TE RAM a-2016; Pembimbing: I. Elih Mulyana; II. Chris Timotius K. K
Uncontrolled Keywords: Kualitas Daya, Total Harmonic Distortion, Susut Tegangan, Cos φ, Kapasitor Bank, Power quality, drop voltage, cos φ, capacitor bank.
Subjects: A General Works > AM Museums (General). Collectors and collecting (General)