PENGEMBANGAN ALAT UKUR WAKTU REAKSI START PELARI JARAK PENDEK BERBASIS MICROCONTROLLER

Saputra, Ridho (2016) PENGEMBANGAN ALAT UKUR WAKTU REAKSI START PELARI JARAK PENDEK BERBASIS MICROCONTROLLER. S1 thesis, Universitas Pendidikan Indonesia.

[img]
Preview
Text
S_IKOR_1206628_Title.pdf

Download (449kB) | Preview
[img]
Preview
Text
S_IKOR_1206628_Abstract.pdf

Download (271kB) | Preview
[img]
Preview
Text
S_IKOR_1206628_Table_of_Content.pdf

Download (141kB) | Preview
[img]
Preview
Text
S_IKOR_1206628_Chapter1.pdf

Download (224kB) | Preview
[img] Text
S_IKOR_1206628_Chapter2.pdf
Restricted to Staf Perpustakaan

Download (442kB)
[img]
Preview
Text
S_IKOR_1206628_Chapter3.pdf

Download (378kB) | Preview
[img] Text
S_IKOR_1206628_Chapter4.pdf
Restricted to Staf Perpustakaan

Download (869kB)
[img]
Preview
Text
S_IKOR_1206628_Chapter5.pdf

Download (141kB) | Preview
[img]
Preview
Text
S_IKOR_1206628_Bibliography.pdf

Download (137kB) | Preview
[img] Text
S_IKOR_1206628_Appendix.pdf
Restricted to Staf Perpustakaan

Download (1MB)
Official URL: http://repository.upi.edu

Abstract

Tujuan dalam penelitian ini ialah membuat sebuah alat pengukur waktu reaksi start pelari jarak pendek berbasis microcontroller. Penelitian ini menggunakan pendekatan metode Research and Development (R&D). Sistem kerja alat ini adalah pada saat push button START ditekan maka timer pada LCD aktif, buzzer berbunyi dan indikator LED menyala, pada saat mendengarkan bunyi dari buzzer, atlet melepaskan tolakan kaki pada start block dan menyebabkan push button yang berada pada start block bagian kanan dan kiri mengirimkan tegangan pada microcontroller ATMega dan menyebabkan timer berhenti dan LED indikator penghentian timer menyala, dari proses tersebut maka diketahui nilai waktu reaksi atlet di LCD, untuk memulai kembali pada proses awal maka dapat menekan push button RESET. Sampel pada penelitian ini dibagi menjadi dua, sampel yang pertama yaitu 30 orang mahasiswa Ilmu Keolahragaan angkatan 2012 dan sampel yang kedua yaitu 5 orang atlet nomor sprint PPLP Atletik Jabar. Sampel yang diambil merupakan bagian dari populasi yang pertama yaitu mahasiswa Ilmu Keolahragaan angkatan 2012 dengan menggunakan teknik simple random sampling dan populasi yang kedua yaitu atlet PPLP atletik Jabar dengan menggunakan teknik sampling purposive. Hasil analisis uji coba menggunakan SPSS 21 dengan sub menu One Sample Kolmogorov Smirnov Z untuk uji normalitas, dan Koefisien Korelasi Bivariate untuk uji hubungan. Hasil analisis menunjukkan bahwa alat ini memiliki nilai validitas yang tinggi yaitu sebesar 0,771 dan nilai reliabilitas yang sangat tinggi yaitu sebesar 0,834. Hasil analisis juga menunjukkan bahwa hubungan antara waktu reaksi start pelari jarak pendek dan waktu tempuh 30 meter tidak memiliki hubungan yang signifikan.;This study aimed at developing a tool to measure the time of sprinters’ starting reaction with microcontroller. The study employed Research and Development (R&D) approach. The tool started to work by pressing the button START. After pressing the button START, the time appeared on the LCD, the buzzer rang, and the indicator of LED turned on. The sprinters began to push their feet away from the starting block when the buzzer rang. Consequently, the button on the starting block transferred the voltage to the microcontroller ATMega, and the timer stoped working. On the other hand, the LED indicator to stop the timer was on. Therefore, the time reaction of those athletes could be seen on the LCD. Additionally, there is a button RESET on that equipment which can be used to restart the program. Furthermore, the sample that was employed in this study was divided into two groups. The first group encompassed 30 students of Sports Science batch 2012, and the second group consisted of 5 athletes of sprint in PPLP athletic Jabar. The first group was taken by using simple random sampling technique, and the other was selected by using purposive sampling technique. The data of the trials were analyzed by using SPSS 21 with sub menu One Sample Kolmogorov-Smirnov Z to test for normality and bivariate correlation coefficient to test the relationship. The results revealed that the tool had a high score in validity namely 0.771 as well as a high score in reliability which was 0.834. Besides that, the results also showed that the relationship between the time of sprinters’ starting reaction and the travel time within 30 meters was not significant.

Item Type: Thesis (S1)
Additional Information: No. Panggil : S IKOR SAP p-2016; Pembimbing : I. Iman Mahmudin, II. Agus Rusdiana.
Uncontrolled Keywords: Waktu reaksi, pelari jarak pendek, pengembangan alat ukur, Reaction time, sprinter, the development of measure tool.
Subjects: R Medicine > RC Internal medicine > RC1200 Sports Medicine
T Technology > T Technology (General)
Divisions: Fakultas Pendidikan Olahraga dan Kesehatan > Jurusan Pendidikan Kesehatan dan Rekreasi > Program Studi IKOR
Depositing User: Mr mhsinf 2017
Date Deposited: 24 Jul 2017 08:03
Last Modified: 24 Jul 2017 08:03
URI: http://repository.upi.edu/id/eprint/23977

Actions (login required)

View Item View Item