ANALISIS PERBAIKAN DROP TEGANGAN PADA JARINGAN TEGANGAN RENDAH MENGGUNAKAN TRAFO SISIPAN DI PENYULANG KACER KOTA PALEMBANG

    Alamsyah Muhammad Saputra, - and Yadi Mulyadi, - (2025) ANALISIS PERBAIKAN DROP TEGANGAN PADA JARINGAN TEGANGAN RENDAH MENGGUNAKAN TRAFO SISIPAN DI PENYULANG KACER KOTA PALEMBANG. S1 thesis, Universitas Pendidikan Indonesia.

    Abstract

    Penelitian ini menganalisis perbaikan drop tegangan pada jaringan tegangan rendah di PT. PLN (Persero) ULP Kenten Kota Palembang, khususnya pada Gardu PB 0504. Permasalahan drop tegangan disebabkan oleh peningkatan beban pada setiap tiang, terutama di ujung tiang. Hasil simulasi menggunakan software ETAP 19.0.1 dan perhitungan Microsoft Excel menunjukkan bahwa sebelum perbaikan, rata-rata drop tegangan mencapai 10,86% pada fasa S dan 9,29% pada fasa T. Nilai ini melampaui batas standar PLN (SPLN No. 1:1995 dan SPLN No. 72:1987) yang menetapkan batas maksimum penurunan tegangan 5% dan tidak melebihi 10% untuk jaringan distribusi. Puncak drop tegangan tertinggi terjadi pada tiang ujung (Tiang 7) dengan 14% pada fasa S dan 12% pada fasa T. Solusi yang diusulkan adalah penambahan transformator distribusi berkapasitas 250 kVA di titik tiang ujung (Tiang 7). Setelah penambahan transformator, simulasi menunjukkan penurunan drop tegangan yang signifikan, menjadi 4% pada fasa S dan 4% pada fasa T di tiang ujung. Secara keseluruhan, rata-rata drop tegangan pada jaringan distribusi setelah perbaikan berada di bawah 5%, sesuai dengan standar PLN. This study analyzes voltage drop improvement in the low-voltage distribution network at PT. PLN (Persero) ULP Kenten, Palembang City, specifically at Distribution Transformer PB 0504. The Voltage Drop issue is caused by increasing load on each utility pole, particularly at the end of the line. Simulation results using ETAP 19.0.1 software and calculations in Microsoft Excel show that before the improvement, the average voltage drop reached 10.86% on phase S and 9.29% on phase T. These values exceed the standard limits set by PLN (SPLN No. 1:1995 and SPLN No. 72:1987), which specify a maximum allowable voltage drop of 5% and not exceeding 10% for distribution networks. The highest voltage drop occurred at the end pole (Pole 7), reaching 14% on phase S and 12% on phase T. the proposed solution is the addition of a 250 kVA distribution transformer at the end pole (Pole 7). After the transformer was added, simulations showed a significant reduction in voltage drop to 4% on both phase S and phase T at the end pole. Overall, the average Voltage Drop across the distribution network after the improvement is below 5%, complying with PLN standards.

    [thumbnail of S_TE_2106142_Title.pdf] Text
    S_TE_2106142_Title.pdf

    Download (750kB)
    [thumbnail of S_TE_2106142_Chapter1.pdf] Text
    S_TE_2106142_Chapter1.pdf

    Download (207kB)
    [thumbnail of S_TE_2106142_Chapter2.pdf] Text
    S_TE_2106142_Chapter2.pdf
    Restricted to Staf Perpustakaan

    Download (562kB) | Request a copy
    [thumbnail of S_TE_2106142_Chapter3.pdf] Text
    S_TE_2106142_Chapter3.pdf

    Download (473kB)
    [thumbnail of S_TE_2106142_Chapter4.pdf] Text
    S_TE_2106142_Chapter4.pdf
    Restricted to Staf Perpustakaan

    Download (308kB) | Request a copy
    [thumbnail of S_TE_2106142_Chapter5.pdf] Text
    S_TE_2106142_Chapter5.pdf

    Download (208kB)
    [thumbnail of S_TE_2106142_Appendix.pdf] Text
    S_TE_2106142_Appendix.pdf
    Restricted to Staf Perpustakaan

    Download (355kB) | Request a copy
    Official URL: https://repository.upi.edu/
    Item Type: Thesis (S1)
    Additional Information: https://scholar.google.com/citations?hl=en&user=CHCNVyYAAAAJ ID SINTA Dosen Pembimbing: Yadi Mulyadi: 6003577
    Uncontrolled Keywords: Drop Tegangan, Jaringan Tegangan Rendah, Transformator Distribusi, ETAP 19.0.1 Voltage Drop, Low Voltage Network, Distribution Transformer, ETAP 19.0.1
    Subjects: L Education > L Education (General)
    T Technology > T Technology (General)
    T Technology > TK Electrical engineering. Electronics Nuclear engineering
    Divisions: Fakultas Pendidikan Teknik dan Industri > Jurusan Pendidikan Teknik Elektro > Program Studi Teknik Tenaga Elektrik